Part Number Hot Search : 
CPC1726Y 000MHZ AP8908 CJSE010 001547 NTE934 IRF640N 2E105
Product Description
Full Text Search
 

To Download D100BP21 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 D100B Series 100 Hz to 100 kHz Low Noise Fixed Frequency
Description: The D100B Series are low noise and distortion 2pole-pair, fixed center frequency (fo) band-pass filters. These filters feature near theoretical low noise and distortion performance, by providing up to -120 dB noise floors (20-Bit). D100B's take advantage of FDI's design expertise utilizing high performance amplifiers and surface-mount technology to provide design engineers with precision signal conditioning solutions in a compact package. These fully self-contained units require no external components or adjustments. Each D100B comes factory tuned to a user specified corner frequency between 100 Hz to 100 kHz. Available Q's for D100B models are 1, 2 or 5 and operate with low harmonic distortion over an input voltage range to 10 V. Features/Benefits: * Small 32-pin DIP (1.8"L x 0.8"W) footprint minimizes board space requirements. * Plug-in ready-to-use, reducing engineering design and manufacturing cycle time. * Factory tuned, no external clocks or adjustments needed. * Broad range of center frequencies to meet a wide range of applications. Applications * * * * * Transducer output filtering. Production test instrumentation Medical electronics equipment and research Noise and harmonic analysis Frequency spectrum analysis Available Band-Pass Models: D100BP2 2-Pole Pair General Specifications Pin-out/package data & order information Page 2 3
2 - Pole Pair Band - Pass Filters
1
1784 Chessie Lane, Ottawa, IL 61350 * Tel: 800/252-7074, 815/434-7800 * FAX: 815/434-8176 e-mail: sales@freqdev.com * Web Address: http://www.freqdev.com
D100B Series 100 Hz to 100 kHz Low Noise Fixed Frequency
Model Product Specifications Size Range fo Available "Q's" 1 "Q" Accuracy Theoretical Transfer Characteristics Pass-Band Gain
(non-inverting)
2 - Pole Pair Band - Pass Filters
D100BP2 1.8" x 0.8" x 0.3" 100 Hz to 100 kHz 1, 2 or 5 10 % Appendix A Pages 39 & 40 0 0.2 dB typ. 0 0.4 dB max. 12 dB/octave 1% max. fo 0.01%/C
Attenuation Rate Center Frequency Stability (THD) Total Harmonic Distortion @ 10 Vp-p FO 100 Hz FO 20 kHz FO 100 kHz Narrow Band Noise
100 kHz BW @ 20V p-p
<-120 dB max. <-117 dB max. <-100 dB max.
FO 100 Hz FO 20 kHz FO 100 kHz Filter Mounting 2 Assembly
(V rms) 7.0 typ., 12 max. 22 typ., 40 max. 70 typ., 100 max. FMA-01S
1. Q - Quality Factor for band-pass and band-reject filters. Q = fO/(fH-fL), fo = fHfL 2. Use I/O jumpers to bypass input and output buffers, for low noise operation. With FMA, D100B distortion specs at 50k to 100kHz may degrade slightly.
2
1784 Chessie Lane, Ottawa, IL 61350 * Tel: 800/252-7074, 815/434-7800 * FAX: 815/434-8176 e-mail: sales@freqdev.com * Web Address: http://www.freqdev.com
D100B Series Specifications
(25C and Vs 15 Vdc)
Analog Input Characteristics1 Impedance Voltage Range Max. Safe Voltage Analog Output Characteristics Load Impedance Linear Operating Range for THD Operating Range for Low Noise 2 Current @ (Vs @ 15V) Offset Voltage3 Offset Temp. Coefficient Power Supply (Vs) Rate Voltage Operating Range Quiescent Current Temperature Range Operating Storage
Pin-Out and Package Data Ordering Information
0.80"(max)
1.0 k min. 10 Vpeak Vs 1.0 k min. 5V 10V 10 mA max. 2 mV typ. 20 mV max. 50 V/C 15V 5V min. 18V max. 40 mA max 0C to +70C -25C to +85C
0.10" 0.00" 0.00" 0.15"
29
FO <10 kHz FO >10 kHz
0.025" (dia) 1.80"(max)
0.50"(max) 0.30"(max)
0.15" (min)
FO <10 kHz FO >10 kHz
0.10"(typ) 0.80" 0.70"
All dimensions are in inches All case dimensions 0.01"
5 15 16
1
OUT
+VS
-VS OS
Bottom View
GND IN
17
DC Offset Adjustment
+Vs Do not connect if trim is not required. 20 k
(Cermet)
0.45" 0.55"
1.55" 1.65"
Os
ORDERING INFORMATION
4
D100BP2/5-10.0 kHz
-Vs
Notes: 1. Input and output signal voltage referenced to supply common. 2. Output is short circuit protected to common. DO NOT CONNECT TO Vs. 3. Adjustable to zero. 4. Units operate with or without offset pin connected. 5. How to specify Center Frequency F0. Center frequency is specified by attaching a three-digit frequency designator to the basic model number. Center frequencies can range from 100 Hz to 100 kHz.
1.80"
"Q" 1, 2, 5
F0 Center Frequency e.g., 849 Hz 2.50 kHz 33.3 kHz
5
We hope the information given here will be helpful. The information is based on data and our best knowledge, and we consider the information to be true and accurate. Please read all statements, recommendations or suggestions herein in conjunction with our conditions of sale, which apply, to all goods supplied by us. We assume no responsibility for the use of these statements, recommendations or suggestions, nor do we intend them as a recommendation for any use, which would infringe any patent or copyright. PR-D100BP2
3
1784 Chessie Lane, Ottawa, IL 61350 * Tel: 800/252-7074, 815/434-7800 * FAX: 815/434-8176 e-mail: sales@freqdev.com * Web Address: http://www.freqdev.com
Band-Pass 2-Pole Pair Appendix A Amplitude Response Curves 0 -10 -20 -30 -40 -50 -60 -70 -80 0.1 0 Amp (dB) Q1 Q2 Q5 Q10 -1 -2 -3 -4 Q10
2 3 4 5 6 78
Q1 Q2
Amp (dB)
Q5
1.0 2 3 4 5 6 7 8 10.0 Normalized Frequency (f/fo)
-5 0.6
0.7
0.8
1.0 1.1 1.2 1.3 1.4 1.5 1.6 Normalized Frequency (f/fo)
0.9
Q=1 Amp fL < fO < fH
Q=2 fL < fO < fH
Q=5 fL < fO < fH
Q = 10 fL < fO < fH
(dB) -0.10 -0.25 -0.50 -1.00 -1.50 -2.00 -2.50 -3.00 -5.00 -10.00 -15.00 -20.00 -25.00 -30.00 -35.00 -40.00 -45.00 -50.00 -55.00 -60.00 -65.00 -70.00 -75.00 -80.00
f /fO 0.824 0.783 0.747 0.705 0.677 0.654 0.635 0.618 0.563 0.457 0.368 0.290 0.225 0.173 0.131 0.099 0.075 0.056 0.042 0.032 0.024 0.018 0.013 0.010
f /fO 1.214 1.277 1.338 1.418 1.478 1.529 1.574 1.617 1.776 2.189 2.720 3.445 4.439 5.795 7.630 10.09 13.41 17.83 23.75 31.65 42.19 56.25 75.00 100.0
f /fO 0.907 0.884 0.863 0.837 0.820 0.805 0.792 0.781 0.742 0.657 0.572 0.485 0.399 0.319 0.250 0.193 0.147 0.111 0.084 0.063 0.047 0.036 0.027 0.020
f /fO 1.102 1.131 1.159 1.194 1.220 1.242 1.262 1.280 1.348 1.523 1.748 2.062 2.506 3.130 3.999 5.192 6.814 9.002 11.94 15.87 21.13 28.15 37.52 50.01
f /fO 0.962 0.952 0.943 0.931 0.923 0.916 0.910 0.905 0.886 0.842 0.792 0.733 0.664 0.585 0.500 0.414 0.333 0.262 0.202 0.154 0.117 0.088 0.066 0.050
f /fO 1.040 1.051 1.061 1.074 1.083 1.091 1.098 1.105 1.129 1.188 1.263 1.364 1.507 1.709 2.000 2.414 3.001 3.819 4.945 6.479 8.552 11.33 15.06 20.05
f /fO 0.981 0.976 0.971 0.965 0.961 0.957 0.954 0.951 0.941 0.917 0.889 0.855 0.811 0.758 0.693 0.618 0.535 0.449 0.365 0.290 0.225 0.172 0.131 0.099
f /fO 1.020 1.025 1.030 1.036 1.041 1.045 1.048 1.051 1.062 1.090 1.125 1.170 1.233 1.320 1.443 1.618 1.869 2.228 2.737 3.453 4.443 5.798 7.632 10.10
39
1784 Chessie Lane, Ottawa, IL 61350 * Tel: 800/252-7074, 815/434-7800 * FAX: 815/434-8176 e-mail: sales@freqdev.com Web Address: http://www.freqdev.com
Band-Pass
2-Pole Pair Appendix A Phase Response Curves 180 Q10 Phase (deg) 90 0 Q1 -90 -180 0.1 Q2 Q5
2 3 4 5 6 78
180 Phase (deg) 90 0 -90 Q10 1.0 2 3 4 5 6 7 8 10.0 Normalized Frequency (f/fo) -180 0.6
0.7 0.8 0.9
Q1 Q2 Q5
1.0 1.1 1.2 1.3 1.4 1.5 1.6 Normalized Frequency (f/fo)
Normalized Theoretical Phase Data
Phase Mag (deg) 1.0 2.5 5.0 10.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0 50.0 60.0 70.0 80.0 90.0 105.0 120.0 135.0 150.0 165.0 180.0 Q=1 (+) (-) f /fO f /fO 0.994 1.006 0.985 1.016 0.970 1.031 0.940 1.063 0.913 1.096 0.886 1.128 0.861 1.161 0.838 1.194 0.815 1.227 0.794 1.259 0.774 1.292 0.755 1.324 0.719 1.391 0.685 1.460 0.652 1.535 0.618 1.618 0.564 1.772 0.502 1.991 0.424 2.356 0.320 3.126 0.177 5.639 0 inf Q=2 (+) (-) f /fO f /fO 0.997 1.003 0.992 1.008 0.985 1.016 0.970 1.031 0.955 1.047 0.941 1.062 0.928 1.078 0.915 1.093 0.902 1.108 0.891 1.123 0.879 1.138 0.868 1.152 0.846 1.182 0.825 1.212 0.803 1.245 0.781 1.281 0.743 1.346 0.695 1.439 0.628 1.594 0.520 1.923 0.327 3.058 0 inf Q=5 (+) (-) f /fO f /fO 0.999 1.001 0.997 1.003 0.994 1.006 0.988 1.012 0.982 1.018 0.976 1.025 0.970 1.030 0.965 1.036 0.960 1.042 0.955 1.048 0.950 1.053 0.945 1.059 0.935 1.069 0.925 1.081 0.916 1.092 0.905 1.105 0.887 1.128 0.862 1.160 0.825 1.212 0.758 1.319 0.593 1.686 0 inf Q = 10 (+) (-) f /fO f /fO 0.999 1.001 0.998 1.002 0.997 1.003 0.994 1.006 0.991 1.009 0.988 1.012 0.985 1.015 0.982 1.018 0.980 1.021 0.977 1.024 0.974 1.026 0.972 1.029 0.967 1.034 0.962 1.040 0.957 1.045 0.951 1.051 0.941 1.062 0.928 1.077 0.908 1.101 0.869 1.150 0.764 1.310 0 inf
40
1784 Chessie Lane, Ottawa, IL 61350 * Tel: 800/252-7074, 815/434-7800 * FAX: 815/434-8176 e-mail: sales@freqdev.com Web Address: http://www.freqdev.com


▲Up To Search▲   

 
Price & Availability of D100BP21

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X